Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biotechnol Prog ; : e3477, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38699906

RESUMO

Media preparation parameters contribute significantly to media quality, cell culture performance, productivity, and product quality. Establishing proper media preparation procedures is critical for ensuring a robust CHO cell culture process. Process analytical technology (PAT) enables unique ways to quantify assessments and improve media quality. Here, cell culture media were prepared under a wide range of temperatures (40-80°C) and pH (7.6-10.0). Media quality profiles were compared using three real-time PATs: Fourier-transform infrared (FTIR) spectroscopy, Raman spectroscopy, and excitation-emission matrix (EEM) spectroscopy. FTIR and Raman spectroscopies identified shifts in media quality under high preparation temperature (80°C) and at differing preparation pH which negatively impacted monoclonal antibody (mAb) production. In fed-batch processes for production of three different mAbs, viable cell density (VCD) and cell viability were mostly unaffected under all media preparation temperatures, while titer and cell specific productivity of mAb decreased when cultured in basal and feed media prepared at 80°C. High feed preparation pH alone was tolerated but cell growth and productivity profiles deviated from the control condition. Further, charge variants (main, acidic, basic species) and glycosylation (G0F, afucosylation, and high mannose) were examined. Statistically significant differences were observed for one or more of these quality attributes with any shifts in media preparation. In this study, we demonstrated strong associations between media preparation conditions and cell growth, productivity, and product quality. The rapid evaluation of media by PAT implementation enabled more comprehensive understanding of different parameters on media quality and consequential effects on CHO cell culture.

2.
Biotechnol Prog ; 39(5): e3349, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37102507

RESUMO

Intensified and continuous processes require fast and robust methods and technologies to monitor product titer for faster analytical turnaround time, process monitoring, and process control. The current titer measurements are mostly offline chromatography-based methods which may take hours or even days to get the results back from the analytical labs. Thus, offline methods will not meet the requirement of real time titer measurements for continuous production and capture processes. FTIR and chemometric based multivariate modeling are promising tools for real time titer monitoring in clarified bulk (CB) harvests and perfusate lines. However, empirical models are known to be vulnerable to unseen variability, specifically a FTIR chemometric titer model trained on a given biological molecule and process conditions often fails to provide accurate predictions of titer in another molecule under different process conditions. In this study, we developed an adaptive modeling strategy: the model was initially built using a calibration set of available perfusate and CB samples and then updated by augmenting spiking samples of the new molecules to the calibration set to make the model robust against perfusate or CB harvest of the new molecule. This strategy substantially improved the model performance and significantly reduced the modeling effort for new molecules.

3.
Biotechnol Bioeng ; 119(2): 423-434, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34778948

RESUMO

The application of process analytical technology (PAT) for biotherapeutic development and manufacturing has been employed owing to technological, economic, and regulatory advantages across the industry. Typically, chromatographic, spectroscopic, and/or mass spectrometric sensors are integrated into upstream and downstream unit operations in in-line, on-line, or at-line fashion to enable real-time monitoring and control of the process. Despite the widespread utility of PAT technologies at various unit operations of the bioprocess, a holistic business value assessment of PAT has not been well addressed in biologics. Thus, in this study, we evaluated PAT technologies based on predefined criteria for their technological attributes such as enablement of better process understanding, control, and high-throughput capabilities; as well as for business attributes such as simplicity of implementation, lead time, and cost reduction. The study involved an industry-wide survey, where input from subject matter industry experts on various PAT tools were collected, assessed, and ranked. The survey results demonstrated on-line liquid Chromatography (LC), in-line Raman, and gas analysis techniques are of high business value especially at the production bioreactor unit operation of upstream processing. In-line variable path-length UV/VIS measurements (VPE), on-line LC, multiangle light scattering (MALS), and automated sampling are of high business value in Protein A purification and polishing steps of the downstream process. We also provide insights, based on our experience in clinical and commercial manufacturing of biologics, into the development and implementation of some of the PAT tools. The results presented in this study are intended to be helpful for the current practitioners of PAT as well as those new to the field to gauge, prioritize and steer their projects for success.


Assuntos
Produtos Biológicos , Biotecnologia , Cromatografia/métodos , Análise Espectral/métodos , Animais , Produtos Biológicos/análise , Produtos Biológicos/química , Produtos Biológicos/isolamento & purificação , Reatores Biológicos , Biotecnologia/métodos , Biotecnologia/normas , Células CHO , Cricetinae , Cricetulus , Tecnologia Farmacêutica
4.
Biotechnol Bioeng ; 118(9): 3593-3603, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34185315

RESUMO

The biopharmaceutical industry is transitioning from currently deployed batch-mode bioprocessing to a highly efficient and agile next-generation bioprocessing with the adaptation of continuous bioprocessing, which reduces capital investment and operational costs. Continuous bioprocessing, aligned with FDA's quality-by-design platform, is designed to develop robust processes to deliver safe and effective drugs. With the deployment of knowledge-based operations, product quality can be built into the process to achieve desired critical quality attributes (CQAs) with reduced variability. To facilitate next-generation continuous bioprocessing, it is essential to embrace a fundamental shift-in-paradigm from "quality-by-testing" to "quality-by-design," which requires the deployment of process analytical technologies (PAT). With the adaptation of PAT, a systematic approach of process and product understanding and timely process control are feasible. Deployment of PAT tools for real-time monitoring of CQAs and feedback control is critical for continuous bioprocessing. Given the current deficiency in PAT tools to support continuous bioprocessing, we have integrated Infinity 2D-LC with a post-flow-splitter in conjunction with the SegFlow autosampler to the bioreactors. With this integrated system, we have established a platform for online measurements of titer and CQAs of monoclonal antibodies as well as amino acid analysis of bioreactor cell culture.


Assuntos
Reatores Biológicos , Técnicas de Cultura de Células , Modelos Teóricos , Anticorpos Monoclonais/biossíntese , Anticorpos Monoclonais/química , Anticorpos Monoclonais/isolamento & purificação , Produtos Biológicos/química , Produtos Biológicos/isolamento & purificação , Produtos Biológicos/metabolismo
5.
Biotechnol Prog ; 37(4): e3177, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34036755

RESUMO

Analytical testing of product quality attributes and process parameters during the biologics development (Process analytics) has been challenging due to the rapid growth of biomolecules with complex modalities to support unmet therapeutic needs. Thus, the expansion of the process analytics tool box for rapid analytics with the deployment of cutting-edge technologies and cyber-physical systems is a necessity. We introduce the term, Process Analytics 4.0; which entails not only technology aspects such as process analytical technology (PAT), assay automation, and high-throughput analytics, but also cyber-physical systems that enable data management, visualization, augmented reality, and internet of things (IoT) infrastructure for real time analytics in process development environment. This review is exclusively focused on dissecting high-level features of PAT, automation, and data management with some insights into the business aspects of implementing during process analytical testing in biologics process development. Significant technological and business advantages can be gained with the implementation of digitalization, automation, and real time testing. A systematic development and employment of PAT in process development workflows enable real time analytics for better process understanding, agility, and sustainability. Robotics and liquid handling workstations allow rapid assay and sample preparation automation to facilitate high-throughput testing of attributes and molecular properties which are otherwise challenging to monitor with PAT tools due to technological and business constraints. Cyber-physical systems for data management, visualization, and repository must be established as part of Process Analytics 4.0 framework. Furthermore, we review some of the challenges in implementing these technologies based on our expertise in process analytics for biopharmaceutical drug substance development.


Assuntos
Produtos Biológicos , Automação , Produtos Biológicos/uso terapêutico , Fluxo de Trabalho
6.
Biotechnol Bioeng ; 117(10): 3182-3198, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32946122

RESUMO

Real-time monitoring of bioprocesses by the integration of analytics at critical unit operations is one of the paramount necessities for quality by design manufacturing and real-time release (RTR) of biopharmaceuticals. A well-defined process analytical technology (PAT) roadmap enables the monitoring of critical process parameters and quality attributes at appropriate unit operations to develop an analytical paradigm that is capable of providing real-time data. We believe a comprehensive PAT roadmap should entail not only integration of analytical tools into the bioprocess but also should address automated-data piping, analysis, aggregation, visualization, and smart utility of data for advanced-data analytics such as machine and deep learning for holistic process understanding. In this review, we discuss a broad spectrum of PAT technologies spanning from vibrational spectroscopy, multivariate data analysis, multiattribute chromatography, mass spectrometry, sensors, and automated-sampling technologies. We also provide insights, based on our experience in clinical and commercial manufacturing, into data automation, data visualization, and smart utility of data for advanced-analytics in PAT. This review is catered for a broad audience, including those new to the field to those well versed in applying these technologies. The article is also intended to give some insight into the strategies we have undertaken to implement PAT tools in biologics process development with the vision of realizing RTR testing in biomanufacturing and to meet regulatory expectations.


Assuntos
Produtos Biológicos , Controle de Qualidade , Tecnologia Farmacêutica
7.
Biotechnol Bioeng ; 117(12): 3766-3774, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32776504

RESUMO

Technologies capable of monitoring product quality attributes and process parameters in real time are becoming popular due to the endorsement of regulatory agencies and also to support the agile development of biotherapeutic pipelines. The utility of vibrational spectroscopic techniques such as Fourier transform mid-infrared (Mid-IR) and multivariate data analysis (MVDA) models allows the prediction of multiple critical attributes simultaneously in real time. This study reports the use of Mid-IR and MVDA model sensors for monitoring of multiple attributes (excipients and protein concentrations) in real time (measurement frequency of every 40 s) at ultrafiltration and diafiltration (UF/DF) unit operation of biologics manufacturing. The platform features integration of fiber optic Mid-IR probe sensors to UF/DF set up at the bulk solution and through a flow cell at the retentate line followed by automated Mid-IR data piping into a process monitoring software platform with pre-loaded partial least square regression (PLS) chemometric models. Data visualization infrastructure is also built-in to the platform so that upon automated PLS prediction of excipients and protein concentrations, the results were projected in a graphical or numerical format in real time. The Mid-IR predicted concentrations of excipients and protein show excellent correlation with the offline measurements by traditional analytical methods. Absolute percent difference values between Mid-IR predicted results and offline reference assay results were ≤5% across all the excipients and the protein of interest; which shows a great promise as a reliable process analytical technology tool.


Assuntos
Anticorpos Monoclonais/biossíntese , Anticorpos Monoclonais/isolamento & purificação , Espectroscopia de Infravermelho com Transformada de Fourier , Ultrafiltração
10.
Chem Sci ; 6(4): 2457-2468, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25798217

RESUMO

Human toxic responses are very often related to metabolism. Liver metabolism is traditionally studied, but other organs also convert chemicals and drugs to reactive metabolites leading to toxicity. When DNA damage is found, the effects are termed genotoxic. Here we describe a comprehensive new approach to evaluate chemical genotoxicity pathways from metabolites formed in-situ by a broad spectrum of liver, lung, kidney and intestinal enzymes. DNA damage rates are measured with a microfluidic array featuring a 64-nanowell chip to facilitate fabrication of films of DNA, electrochemiluminescent (ECL) detection polymer [Ru(bpy)2(PVP)10]2+ {(PVP = poly(4-vinylpyridine)} and metabolic enzymes. First, multiple enzyme reactions are run on test compounds using the array, then ECL light related to the resulting DNA damage is measured. A companion method next facilitates reaction of target compounds with DNA/enzyme-coated magnetic beads in 96 well plates, after which DNA is hydrolyzed and nucleobase-metabolite adducts are detected by LC-MS/MS. The same organ enzymes are used as in the arrays. Outcomes revealed nucleobase adducts from DNA damage, enzymes responsible for reactive metabolites (e.g. cyt P450s), influence of bioconjugation, relative dynamics of enzymes suites from different organs, and pathways of possible genotoxic chemistry. Correlations between DNA damage rates from the cell-free array and organ-specific cell-based DNA damage were found. Results illustrate the power of the combined DNA/enzyme microarray/LC-MS/MS approach to efficiently explore a broad spectrum of organ-specific metabolic genotoxic pathways for drugs and environmental chemicals.

11.
Soft Matter ; 10(41): 8145-56, 2014 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-25209428

RESUMO

Complex functional films containing enzymes and other biomolecules are easily fabricated in nm-scale thicknesses by using layer-by-layer (LbL) methodologies first popularized by Lvov and Decher. In this review, we highlight the high level functional capabilities possible with LbL films of biomolecules based on our own research experiences. We first describe the basics of enzyme film fabrication by LbL alternate electrostatic adsorption, then discuss how to make functional enzyme-polyion films of remarkably high stability. Focusing on cytochrome P450s, we discuss films developed to electrochemically activate the natural catalytic cycle of these key metabolic enzymes. We then describe multifunctional, multicomponent DNA/enzyme/polyion films on arrays and particle surfaces for high throughput metabolic toxicity screening using electrochemiluminescence and LC-MS/MS. Using multicomponent LbL films, complex functionality for bioanalytical and biochemical purposes can be achieved that is difficult or impossible using conventional approaches.


Assuntos
Reatores Biológicos , Sistema Enzimático do Citocromo P-450/química , Enzimas Imobilizadas/química , Adsorção , DNA/química
12.
Lab Chip ; 13(23): 4554-62, 2013 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-24113555

RESUMO

A high throughput electrochemiluminescent (ECL) chip was fabricated and integrated into a fluidic system for screening toxicity-related chemistry of drug and pollutant metabolites. The chip base is conductive pyrolytic graphite onto which are printed 64 microwells capable of holding one-µL droplets. Films combining DNA, metabolic enzymes and an ECL-generating ruthenium metallopolymer (Ru(II)PVP) are fabricated in these microwells. The system runs metabolic enzyme reactions, and subsequently detects DNA damage caused by reactive metabolites. The performance of the chip was tested by measuring DNA damage caused by metabolites of the well-known procarcinogen benzo[a]pyrene (B[a]P). Liver microsomes and cytochrome P450 (cyt P450) enzymes were used with and without epoxide hydrolase (EH), a conjugative enzyme required for multi-enzyme bioactivation of B[a]P. DNA adduct formation was confirmed by determining specific DNA-metabolite adducts using similar films of DNA/enzyme on magnetic bead biocolloid reactors, hydrolyzing the DNA, and analyzing by capillary liquid chromatography-mass spectrometry (CapLC-MS/MS). The fluidic chip was also used to measure IC50-values of inhibitors of cyt P450s. All results show good correlation with reported enzyme activity and inhibition assays.


Assuntos
Benzo(a)pireno/metabolismo , Ensaios de Triagem em Larga Escala , Medições Luminescentes , Técnicas Analíticas Microfluídicas/instrumentação , Testes de Mutagenicidade/instrumentação , Testes de Mutagenicidade/métodos , Animais , Benzo(a)pireno/química , Benzo(a)pireno/toxicidade , Bovinos , Complexos de Coordenação/química , Inibidores das Enzimas do Citocromo P-450 , Sistema Enzimático do Citocromo P-450/metabolismo , DNA/química , DNA/metabolismo , Adutos de DNA/análise , Dano ao DNA/efeitos dos fármacos , Poluentes Ambientais/toxicidade , Epóxido Hidrolases/metabolismo , Humanos , Medições Luminescentes/instrumentação , Microssomos Hepáticos/metabolismo , Rutênio/química , Espectrometria de Massas em Tandem
13.
Analyst ; 138(1): 171-8, 2013 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-23095952

RESUMO

A multiplexed, microfluidic platform to detect reactive metabolites is described, and its performance is illustrated for compounds metabolized by oxidative and bioconjugation enzymes in multi-enzyme pathways to mimic natural human drug metabolism. The device features four 8-electrode screen printed carbon arrays coated with thin films of DNA, a ruthenium-polyvinylpyridine (RuPVP) catalyst, and multiple enzyme sources including human liver microsomes (HLM), cytochrome P450 (cyt P450) 1B1 supersomes, microsomal epoxide hydrolase (EH), human S9 liver fractions (Hs9) and N-acetyltransferase (NAT). Arrays are arranged in parallel to facilitate multiple compound screening, enabling up to 32 enzyme reactions and measurements in 20-30 min. In the first step of the assay, metabolic reactions are achieved under constant flow of oxygenated reactant solutions by electrode driven natural catalytic cycles of cyt P450s and cofactor-supported bioconjugation enzymes. Reactive metabolites formed in the enzyme reactions can react with DNA. Relative DNA damage is measured in the second assay step using square wave voltammetry (SWV) with RuPVP as catalyst. Studies were done on chemicals known to require metabolic activation to induce genotoxicity, and results reproduced known features of metabolite DNA-reactivity for the test compounds. Metabolism of benzo[a]pyrene (B[a]P) by cyt P450s and epoxide hydrolase showed an enhanced relative DNA damage rate for DNA compared to cyt P450s alone. DNA damage rates for arylamines by pathways featuring both oxidative and conjugative enzymes at pH 7.4 gave better correlation with rodent genotoxicity metric TD(50). Results illustrate the broad utility of the reactive metabolite screening device.


Assuntos
Enzimas/metabolismo , Técnicas Analíticas Microfluídicas/métodos , Aminas/química , Aminas/metabolismo , Eletroquímica , Humanos , Compostos Organometálicos/química , Oxirredução , Preparações Farmacêuticas/metabolismo , Reprodutibilidade dos Testes
14.
Anal Chem ; 84(23): 10485-91, 2012 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-23121341

RESUMO

We report here the first kinetic characterization of 1 µm diameter superparamagnetic particles (MP) decorated with over 100,000 antibodies binding to protein antigens attached to flat surfaces. Surface plasmon resonance (SPR) was used to show that these antibody-derivatized MPs (MP-Ab(2)) exhibit irreversible binding with 100-fold increased association rates compared to free antibodies. The estimated upper limit for the dissociation constant of MP-Ab(2) from the SPR sensor surface is 5 fM, compared to 3-8 nM for the free antibodies. These results are explained by up to 2000 interactions of MP-Ab(2) with protein-decorated surfaces. Findings are consistent with highly efficient capture of protein antigens in solution by the MP-Ab(2) and explain in part the utility of these beads for ultrasensitive protein detection into the fM and aM range. Aggregation of these particles on the SPR chip, probably due to residual magnetic microdomains in the particles, also contributes to ultrasensitive detection and may also help drive the irreversible binding.


Assuntos
Anticorpos/imunologia , Técnicas Biossensoriais , Proteínas Imobilizadas/metabolismo , Interleucina-6/metabolismo , Calicreínas/metabolismo , Nanopartículas de Magnetita , Antígeno Prostático Específico/metabolismo , Anticorpos/metabolismo , Ouro/química , Humanos , Proteínas Imobilizadas/imunologia , Interleucina-6/imunologia , Calicreínas/imunologia , Antígeno Prostático Específico/imunologia , Ressonância de Plasmônio de Superfície
15.
Electroanalysis ; 24(11): 2049-2052, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23626453

RESUMO

The natural catalytic cycle of cytochrome (cyt) P450 enzymes in human liver microsome (HLM) films was activated electrochemically via the electron transfer sequence electrode→cyt P450 reductase (CPR)→cyt P450. Cyclic voltammograms for HLM films had midpoint potentials of -0.50 V vs. SCE at pH 7.4 characteristic of CPR, not cyt P450s. HLM and CPR microsomes without cyt P450s did not electrocatalytically reduce H2O2, and did not shift midpoint potential when CO was added, also indicating that the peaks do not correspond to iron heme cyt P450 enzymes. Electrochemical activation of the natural cyt P450 cycle for substrate conversion via CPR in HLM films was confirmed by catalytic electrolysis in an electrochemical microfluidic array designed to generate and detect reactive metabolites by measuring their reactivity with DNA.

16.
Anal Chem ; 83(24): 9499-506, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-22040095

RESUMO

A novel, simple, rapid microfluidic array using bioelectronically driven cytochrome P450 enzyme catalysis for reactive metabolite screening is reported for the first time. The device incorporates an eight-electrode screen-printed carbon array coated with thin films of DNA, [Ru(bpy)(2)(PVP)(10)](ClO(4)) {RuPVP}, and rat liver microsomes (RLM) as enzyme sources. Catalysis features electron donation to cyt P450 reductase in the RLMs and subsequent cyt P450 reduction while flowing an oxygenated substrate solution past sensor electrodes. Metabolites react with DNA in the film if they are able, and damaged DNA is detected by catalytic square wave voltammetry (SWV) utilizing the RuPVP polymer. The microfluidic device was tested for a set of common pollutants known to form DNA-reactive metabolites. Logarithmic turnover rates based on SWV responses gave excellent correlation with the rodent liver TD(50) toxicity metric, supporting the utility of the device for toxicity screening. The microfluidic array gave much better S/N and reproducibility than single-electrode sensors based on similar principles.


Assuntos
Sistema Enzimático do Citocromo P-450/metabolismo , Técnicas Eletroquímicas , Técnicas Analíticas Microfluídicas , Animais , Complexos de Coordenação/química , DNA/química , DNA/metabolismo , Adutos de DNA/análise , Dano ao DNA , Eletrodos , Microssomos Hepáticos/enzimologia , Ratos , Rutênio/química
18.
J Am Chem Soc ; 133(5): 1459-65, 2011 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-21214177

RESUMO

Cytochrome (cyt) P450s comprise the enzyme superfamily responsible for human oxidative metabolism of a majority of drugs and xenobiotics. Electronic delivery of electrons to cyt P450s could be used to drive the natural catalytic cycle for fundamental investigations, stereo- and regioselective synthesis, and biosensors. We describe herein 30 nm nanometer-thick films on electrodes featuring excess human cyt P450s and cyt P450 reductase (CPR) microsomes that efficiently mimic the natural catalytic pathway for the first time. Redox potentials, electron-transfer rates, CO-binding, and substrate conversion rates confirmed that electrons are delivered from the electrode to CPR, which transfers them to cyt P450. The film system enabled electrochemical probing of the interaction between cyt P450 and CPR for the first time. Agreement of film voltammetry data with theoretical simulations supports a pathway featuring a key equilibrium redox reaction in the natural catalytic pathway between reduced CPR and cyt P450 occurring within a CPR-cyt P450 complex uniquely poised for substrate conversion.


Assuntos
Biocatálise , Sistema Enzimático do Citocromo P-450/metabolismo , Elétrons , Monóxido de Carbono/metabolismo , Sistema Enzimático do Citocromo P-450/química , Eletroquímica , Eletrodos , Transporte de Elétrons , Humanos , Cinética , Microssomos/enzimologia , NADP/metabolismo , NADPH-Ferri-Hemoproteína Redutase/química , NADPH-Ferri-Hemoproteína Redutase/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...